Vehicle Water Leak Test Facilities

DRYSYS designs and constructs vehicle water leak test facilities for the verification of body sealing and weather performance. Systems are engineered to simulate controlled rainfall conditions, ensuring vehicles meet specified build and quality requirements.

Facilities are customised to suit different vehicle types and production environments, and are typically integrated into manufacturing or test lines.

System Design

Water leak test facilities are configured to meet specific test criteria and operational requirements, incorporating:

  • Controlled water flow and pressure systems

  • Traversing gantry or drive-through configurations

  • Water collection, storage, and recirculation systems

  • PLC-based control with HMI interface

  • Integration with production lines and plant services

Systems are designed to provide repeatable and consistent test conditions across all vehicles.

Key Features

  • Engineered to suit vehicle size, geometry, and test requirements

  • Controlled application of water flow, pressure, and test duration

  • Repeatable and measurable test conditions

  • Integration with automated production and testing systems

  • Configurable for new installations or upgrades to existing facilities

System Capabilities

  • Traversing gantry (roll-over) systems

  • Drive-through test facilities

  • In-ground or above-ground water storage systems

  • Water recirculation and treatment systems

  • PLC and HMI-based control systems

  • Monitoring of flow rates, pressure, and test cycles

Typical Applications

  • Automotive and commercial vehicle manufacturing

  • Rail and rolling stock

  • Aerospace and defence applications

  • Specialised vehicle and equipment testing

 